Address DC: Frt Corner Rdar 2 (J1088) Labels:* None
Part No SW: 4N0 907 669 K HW: 4N0 907 669 A
Component: MRR_VL H14 0485
Dataset Number: 4M1909483B 0005
Coding: 001000
Shop #: WSC 31414 039 00001
ASAM Dataset: EV_FrontCorneRadarS2AU651 001022
ROD: EV_FrontCorneRadarS2AU651_AU73.rod
VCID: 42DD4A15740C2FCA797-8016
2 Faults Found:
1183796 - Databus
U1121 00 [00001000] - Missing Message
[databus message missing - SARA_11]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 110
Mileage: 63064 km
Date: 2023.12.12
Time: 14:56:56
Control Module temperature: 23 C
Voltage terminal 30: Measuring value not available
Vehicle speed: 0.00 km/h
Terminal 15 status: On
Voltage terminal 15: 12.80 V
Register_check_info-Register_check_info_parameter: 0
C1_critical_signals_info-C1_critical_signals_info_parameter: 4294967295
C2_critical_signals_info-C2_critical_signals_info_parameter: 4294967295
1183797 - Databus
U1123 00 [00001000] - Received Error Message
[Timestamp_databus_message_missing_Airbag_05]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 1
Reset counter: 110
Mileage: 63064 km
Date: 2023.12.12
Time: 14:56:56
Control Module temperature: 23 C
Voltage terminal 30: Measuring value not available
Vehicle speed: 0.00 km/h
Terminal 15 status: On
Voltage terminal 15: 12.70 V
Register_check_info-Register_check_info_parameter: 0
C1_critical_signals_info-C1_critical_signals_info_parameter: 4294967295
C2_critical_signals_info-C2_critical_signals_info_parameter: 4294967295