Lane Chge Asst 2 4N0 907 566 K coding and module information (4N0907566K)

Coding for Lane Chge Asst 2 4N0907566K / 4N0907566A

4N0 907 566 K :H14 / :0486
Coding: 1F  DC  00 

label: None
# Byte 0 [1F] / Binary: 00011111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [DC] / Binary: 11011100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address CF: Lane Chge Asst 2 (J770)       Labels:* None
   Part No SW: 4N0 907 566 K    HW: 4N0 907 566 A
   Component: MRR_HL H14 0486  
   Dataset Number: 4M1909468B  0005
   Coding: 1FDC00
   Shop #: WSC 31414 039 00001
   ASAM Dataset: EV_RearRadarS2DelphAU651 001022
   ROD: EV_RearRadarS2DelphAU651_AU73.rod
   VCID: 3E253EE500F44B2A1DF-806A
 
8 Faults Found:
1183747 - Databus 
          U1121 00 [00001000] - Missing Message
          [databus message missing - SARA_11]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 14:56:54
 
                    Control Module temperature: 21  C
                    Voltage terminal 30: 12.90 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available
 
1183797 - Databus 
          U1123 00 [00001000] - Received Error Message
          [Timestamp_databus_message_missing_Airbag_05]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 14:56:54
 
                    Control Module temperature: 21  C
                    Voltage terminal 30: 12.90 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available
 
1183789 - Databus 
          U1121 00 [00001000] - Missing Message
          [databus message missing - MRR_HR_SensorHeader_01]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 14:56:54
 
                    Control Module temperature: 21  C
                    Voltage terminal 30: 12.90 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available
 
1184001 - Databus 
          U1121 00 [00001000] - Missing Message
          [databus message missing - MRR_HR_Detection]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 14:56:54
 
                    Control Module temperature: 21  C
                    Voltage terminal 30: 12.90 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available
 
1183774 - Databus 
          U1121 00 [00001000] - Missing Message
          [databus message missing - MRR_HR_SensorHeader]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 14:56:54
 
                    Control Module temperature: 21  C
                    Voltage terminal 30: 12.90 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available
 
1191985 - Databus 
          U1123 00 [00001000] - Received Error Message
          [databus error value received - SARA_11_SARA_CF_Omega_Z_r]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 16:50:28
 
                    Control Module temperature: 16  C
                    Voltage terminal 30: 11.70 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available
 
2232321 - Databus 
          U1121 00 [00001000] - Missing Message
          [databus message missing - Anhaenger_01]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63084 km
                    Date: 2023.12.13
                    Time: 14:10:08
 
                    Control Module temperature: 26  C
                    Voltage terminal 30: 13.00 V
                    Vehicle speed: Malfunction
                    Terminal 15 status: OFF
                    Voltage terminal 15: Measuring value not available
 
2232336 - Databus 
          U1121 00 [00001000] - Missing Message
          [databus message missing - MRR_HR_01]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 110
                    Mileage: 63064 km
                    Date: 2023.12.12
                    Time: 14:56:59
 
                    Control Module temperature: 21  C
                    Voltage terminal 30: 12.90 V
                    Vehicle speed: 0.00 km/h
                    Terminal 15 status: On
                    Voltage terminal 15: Measuring value not available