Address C6: Batt. Chrg. (J1050) Labels:| 1EA-915-684.clb
Part No SW: 1EA 915 684 EA HW: 1EA 915 684 BK
Component: HV_CHARGER H60 1019
Serial number: 93286UGD0000I
Coding: 1080
ASAM Dataset: EV_OCCXPhase1KLOMEB01B 002017
ROD: EV_OCCXPhase1KLOMEB01B.rod
VCID: 7EA6F473A07872DA5DF-802A
5 Faults Found:
3276840 - Intelligent Charging
U15A9 00 [01101000] - Functional Restriction
[ETHTRCV_30_AR7000_E_ACCESS]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 2
Reset counter: 21
Mileage: 41972 km
Date: 2024.01.28
Time: 22:05:42
DID 1DA0: AC main charge
DID 1DAC: Charging
Frequency: 1000 Hz
Control voltage: 6056.0 mV
Duty cycle: 16.1 %
Activation charge cover lock charge socket A: not requested
Lock for high-voltage charging connector: locked
Status connect. recognition: detected
Charge socket temperature sensor AC: 30.0 °C
Temperature sensor 1: resistance value: 1095 Ohm
DID 15E2: 14.0 °C
DID 081C: 0 W
DID 081D: 1 W
DID 081E: 2108 W
DID 0286: 13.3 V
DID 497C: not active
DID 537A: 14.3 V
DID 1525: 3870 mV
DID 4219: High voltage power off not recognized
DID 5372: 13.0 °C
No. of lockings: 3180
No. of connections: 171
Number of successful charging connector locks: 963
Wake-up counter: contact (proximity): 0
Wake-up counter: Control Pilot: 1
Charging standard abort: status: not active
Loading plan: status: Not available
Price/performance table: status: Not available
Transport Layer Security (TLS) status communication: not active
DID 103A: supported
number_evse_slac: 0
PLC_modem_status: not active
number_slac_attemps: 0
DID 1033: no_active_link
DID 1038: no_description
DID 1039: supported
Target HV charge current: 5.1 A
Powerline communication: charging process status: Standby
3280897 - Charging Station
B1AD0 F0 [01101101] - Identification Failed
[ETHTRCV_30_AR7000_SLAC_STEP_1_SET_CCO_Timeout]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 39
Reset counter: 40
Mileage: 40068 km
Date: 2023.12.29
Time: 18:45:06
DID 1DA0: AC main charge
DID 1DAC: Charging
Frequency: 1000 Hz
Control voltage: 6104.0 mV
Duty cycle: 16.1 %
Activation charge cover lock charge socket A: not requested
Lock for high-voltage charging connector: locked
Status connect. recognition: detected
Charge socket temperature sensor AC: 30.0 °C
Temperature sensor 1: resistance value: 1100 Ohm
DID 15E2: 9.0 °C
DID 081C: 0 W
DID 081D: 1 W
DID 081E: 2278 W
DID 0286: 13.4 V
DID 497C: not active
DID 537A: 14.3 V
DID 1525: 3891 mV
DID 4219: High voltage power off not recognized
DID 5372: 8.0 °C
No. of lockings: 3049
No. of connections: 147
Number of successful charging connector locks: 927
Wake-up counter: contact (proximity): 0
Wake-up counter: Control Pilot: 0
Charging standard abort: status: not active
Loading plan: status: Not available
Price/performance table: status: Not available
Transport Layer Security (TLS) status communication: not active
DID 103A: supported
number_evse_slac: 0
PLC_modem_status: active
number_slac_attemps: 3
DID 1033: SLAC_failed
DID 1038: no_description
DID 1039: supported
Target HV charge current: 5.6 A
Powerline communication: charging process status: Standby
3280899 - Charging Station
B1AD0 F0 [01101101] - Identification Failed
[ETHTRCV_30_AR7000_SLAC_STEP_3_PARAM_REQ_Timeout]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 28891 km
Date: 2023.05.15
Time: 15:18:08
DID 1DA0: AC main charge
DID 1DAC: Charging
Frequency: 1002 Hz
Control voltage: 6049.0 mV
Duty cycle: 50.9 %
Activation charge cover lock charge socket A: not requested
Lock for high-voltage charging connector: locked
Status connect. recognition: detected
Charge socket temperature sensor AC: 30.0 °C
Temperature sensor 1: resistance value: 1090 Ohm
DID 15E2: 18.0 °C
DID 081C: 3 W
DID 081D: 3538 W
DID 081E: 3524 W
DID 0286: 13.3 V
DID 497C: not active
DID 537A: 14.4 V
DID 1525: 1966 mV
DID 4219: High voltage power off not recognized
DID 5372: 17.0 °C
No. of lockings: 2198
No. of connections: 1
Number of successful charging connector locks: 699
Wake-up counter: contact (proximity): 0
Wake-up counter: Control Pilot: 0
Charging standard abort: status: not active
Loading plan: status: Not available
Price/performance table: status: Not available
Transport Layer Security (TLS) status communication: not active
DID 103A: supported
number_evse_slac: 0
PLC_modem_status: active
number_slac_attemps: 1
DID 1033: SLAC_active
DID 1038: no_description
DID 1039: supported
Target HV charge current: 17.3 A
Powerline communication: charging process status: Standby
5242881 - Communication Authentication
U3035 00 [01100000] - Invalid Signal
[SOK_signature_verification_failed]
Intermittent - Not Confirmed - Tested Since Memory Clear
14750981 - Charging Socket 1
P1CF6 00 [01100000] - Unlock Prohibited
[Plug_unlocking_error]
Intermittent - Not Confirmed - Tested Since Memory Clear