Batt. Chrg. - 1EA 915 684 EA

Coding for Batt. Chrg. 1EA915684EA on ID.3

1EA 915 684 EA :H60 / :1019
Coding: 10  80 
label: 1EA-915-684.clb
Faults: 5
Fault 3276840: Intelligent Charging
: Functional Restriction
Fault 3280897: Charging Station
: Identification Failed
Fault 3280899: Charging Station
: Identification Failed
Fault 5242881: Communication Authentication
: Invalid Signal
Fault 14750981: Charging Socket 1
: Unlock Prohibited
# Byte 0 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [80] / Binary: 10000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address C6: Batt. Chrg. (J1050)       Labels:| 1EA-915-684.clb
   Part No SW: 1EA 915 684 EA    HW: 1EA 915 684 BK
   Component: HV_CHARGER    H60 1019  
   Serial number: 93286UGD0000I  
   Coding: 1080
   ASAM Dataset: EV_OCCXPhase1KLOMEB01B 002017
   ROD: EV_OCCXPhase1KLOMEB01B.rod
   VCID: 7EA6F473A07872DA5DF-802A
 
5 Faults Found:
3276840 - Intelligent Charging 
          U15A9 00 [01101000] - Functional Restriction
          [ETHTRCV_30_AR7000_E_ACCESS]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 2
                    Reset counter: 21
                    Mileage: 41972 km
                    Date: 2024.01.28
                    Time: 22:05:42
 
                    DID 1DA0: AC main charge
                    DID 1DAC: Charging
                    Frequency: 1000 Hz
                    Control voltage: 6056.0 mV
                    Duty cycle: 16.1 %
                    Activation charge cover lock charge socket A: not requested
                    Lock for high-voltage charging connector: locked
                    Status connect. recognition: detected
                    Charge socket temperature sensor AC: 30.0 °C
                    Temperature sensor 1: resistance value: 1095 Ohm
                    DID 15E2: 14.0 °C
                    DID 081C: 0 W
                    DID 081D: 1 W
                    DID 081E: 2108 W
                    DID 0286: 13.3 V
                    DID 497C: not active
                    DID 537A: 14.3 V
                    DID 1525: 3870 mV
                    DID 4219: High voltage power off not recognized
                    DID 5372: 13.0 °C
                    No. of lockings: 3180
                    No. of connections: 171
                    Number of successful charging connector locks: 963
                    Wake-up counter: contact (proximity): 0
                    Wake-up counter: Control Pilot: 1
                    Charging standard abort: status: not active
                    Loading plan: status: Not available
                    Price/performance table: status: Not available
                    Transport Layer Security (TLS) status communication: not active
                    DID 103A: supported
                    number_evse_slac: 0
                    PLC_modem_status: not active
                    number_slac_attemps: 0
                    DID 1033: no_active_link
                    DID 1038: no_description
                    DID 1039: supported
                    Target HV charge current: 5.1 A
                    Powerline communication: charging process status: Standby
 
3280897 - Charging Station 
          B1AD0 F0 [01101101] - Identification Failed
          [ETHTRCV_30_AR7000_SLAC_STEP_1_SET_CCO_Timeout]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 39
                    Reset counter: 40
                    Mileage: 40068 km
                    Date: 2023.12.29
                    Time: 18:45:06
 
                    DID 1DA0: AC main charge
                    DID 1DAC: Charging
                    Frequency: 1000 Hz
                    Control voltage: 6104.0 mV
                    Duty cycle: 16.1 %
                    Activation charge cover lock charge socket A: not requested
                    Lock for high-voltage charging connector: locked
                    Status connect. recognition: detected
                    Charge socket temperature sensor AC: 30.0 °C
                    Temperature sensor 1: resistance value: 1100 Ohm
                    DID 15E2: 9.0 °C
                    DID 081C: 0 W
                    DID 081D: 1 W
                    DID 081E: 2278 W
                    DID 0286: 13.4 V
                    DID 497C: not active
                    DID 537A: 14.3 V
                    DID 1525: 3891 mV
                    DID 4219: High voltage power off not recognized
                    DID 5372: 8.0 °C
                    No. of lockings: 3049
                    No. of connections: 147
                    Number of successful charging connector locks: 927
                    Wake-up counter: contact (proximity): 0
                    Wake-up counter: Control Pilot: 0
                    Charging standard abort: status: not active
                    Loading plan: status: Not available
                    Price/performance table: status: Not available
                    Transport Layer Security (TLS) status communication: not active
                    DID 103A: supported
                    number_evse_slac: 0
                    PLC_modem_status: active
                    number_slac_attemps: 3
                    DID 1033: SLAC_failed
                    DID 1038: no_description
                    DID 1039: supported
                    Target HV charge current: 5.6 A
                    Powerline communication: charging process status: Standby
 
3280899 - Charging Station 
          B1AD0 F0 [01101101] - Identification Failed
          [ETHTRCV_30_AR7000_SLAC_STEP_3_PARAM_REQ_Timeout]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 28891 km
                    Date: 2023.05.15
                    Time: 15:18:08
 
                    DID 1DA0: AC main charge
                    DID 1DAC: Charging
                    Frequency: 1002 Hz
                    Control voltage: 6049.0 mV
                    Duty cycle: 50.9 %
                    Activation charge cover lock charge socket A: not requested
                    Lock for high-voltage charging connector: locked
                    Status connect. recognition: detected
                    Charge socket temperature sensor AC: 30.0 °C
                    Temperature sensor 1: resistance value: 1090 Ohm
                    DID 15E2: 18.0 °C
                    DID 081C: 3 W
                    DID 081D: 3538 W
                    DID 081E: 3524 W
                    DID 0286: 13.3 V
                    DID 497C: not active
                    DID 537A: 14.4 V
                    DID 1525: 1966 mV
                    DID 4219: High voltage power off not recognized
                    DID 5372: 17.0 °C
                    No. of lockings: 2198
                    No. of connections: 1
                    Number of successful charging connector locks: 699
                    Wake-up counter: contact (proximity): 0
                    Wake-up counter: Control Pilot: 0
                    Charging standard abort: status: not active
                    Loading plan: status: Not available
                    Price/performance table: status: Not available
                    Transport Layer Security (TLS) status communication: not active
                    DID 103A: supported
                    number_evse_slac: 0
                    PLC_modem_status: active
                    number_slac_attemps: 1
                    DID 1033: SLAC_active
                    DID 1038: no_description
                    DID 1039: supported
                    Target HV charge current: 17.3 A
                    Powerline communication: charging process status: Standby
 
5242881 - Communication Authentication 
          U3035 00 [01100000] - Invalid Signal
          [SOK_signature_verification_failed]
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
14750981 - Charging Socket 1 
          P1CF6 00 [01100000] - Unlock Prohibited
          [Plug_unlocking_error]
          Intermittent - Not Confirmed - Tested Since Memory Clear