Address 19: CAN Gateway (J533) Labels:* None
Part No SW: 4G0 907 468 E HW: 4G0 907 468 A
Component: J533--Gateway H08 0213
Revision: -------- Serial number: 00000000207893
Coding: 00CD077D00
Shop #: WSC 02391 785 00200
ASAM Dataset: EV_GatewUDS 001025
ROD: EV_GatewUDS_AU57.rod
VCID: 323D18E174A0721BB56-8066
Battery Monitoring Control Module:
Subsystem 1 - Part No SW: 8X0 915 181 HW: 8X0 915 181
Component: J367-BDM H07 0140
Serial number: 00000000005650150348
Voltage stabilizer:
Subsystem 2 - Part No SW: 8K0 959 663 B HW: 8K0 959 663 B
Component: J532_DCDCStab H05 0006
Serial number: 11200000965011200410
1 Fault Found:
12291 - Energy Management Active
U140B 00 [008] - -
[Powermanagement active]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 7
Fault Frequency: 1
Reset counter: 228
Mileage: 198729 km
Date: 2021.11.27
Time: 11:09:15
Voltage terminal 30: 11.6 V
Voltage terminal 15: 0.0 V
Control Module temperature: 17 °C
System status: Awake_Timer_active
IN ESP_standstill flag: standstill detected
Engine running: OFF
IN ZAS_Te_X: OFF
Terminal 15 status via CAN: OFF
Terminal 15 status: OFF
Datenfeld: 1