Address 19: CAN Gateway (J533) Labels: 1EA-937-012.clb
Part No SW: 1EA 937 012 P HW: 1EA 937 012 A
Component: ICAS1 Host-SG 065 0297
Serial number: SJ8ICS061021117 Dataset Number: V03935364VL 0001
GVL: 2D0000002608508C8062904048180040C000400000060000000000000000C057
ASAM Dataset: EV_GatewICAS1MEB 005001
ROD: EV_GatewICAS1MEB.rod
VCID: 3D24337FEDFEA9C2045-8068 SFD
Battery Monitoring Control Module:
Subsystem 1 - Part No SW: 1EA 915 181 B HW: 1EA 915 181 A
Component: J367-BDMConti H04 1074
Serial number: 773861020021111203C2
Anti-theft alarm system sensor:
Subsystem 2 - Part No SW: 5Q0 951 172 A HW: 5Q0 951 172 B
Component: Sensor, DWA 005 0403
Serial number: 000000000ZL21319N14Y
Alarm horn:
Subsystem 3 - Part No SW: 5Q0 951 605 A HW: 5Q0 951 605 A
Component: Sirene, DWA 005 0314
Serial number: 00000000000050177928
Multifunction steering wheel control module:
Subsystem 4 - Part No SW: 1EA 959 442 H HW: 1EA 959 442
Component: MFL H08 0032
Serial number: 17029815092032100267
22 Faults Found:
8471814 - Databus
U1123 00 [00101110] - Received Error Message
[error_value_ESC_50_EPB_Fehlerstatus_02]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Reset counter: 40
Date: 2023.05.12
Time: 17:04:23
8540417 - EgoMaster
U15FA 00 [00100100] - Input Data Error
Intermittent - Not Confirmed - Tested Since Memory Clear
7467521 - Data Set Implausible
B2012 00 [00101111] - -
[Data_set_implausible_CMS]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 40
Mileage: 28849 km
Date: 2023.05.12
Time: 14:12:17
7467522 - Data Set Implausible
B2012 00 [00101111] - -
[Data_set_implausible_HLC]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 40
Mileage: 28849 km
Date: 2023.05.12
Time: 14:12:17
8491266 - Secure Onboard Communication
U14FE 00 [00101111] - Signature Verification Failed
[SOK_signature_verification_failed]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 1
Reset counter: 40
Mileage: 28849 km
Date: 2023.05.12
Time: 14:13:17
8511745 - Unknown Error Code
U173E 00 [00100100] - -
[Occupant_Presence_Service_Restriction]
Intermittent - Not Confirmed - Tested Since Memory Clear
9371914 - Predictive Route Data
B1630 02 [00101110] - Signal Failure
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Reset counter: 40
Mileage: 28850 km
Date: 2023.05.12
Time: 14:21:51
1048916 - Local Data Bus 4
U10DC 00 [00100100] - Electrical Malfunction
Intermittent - Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 3
Mileage: 37739 km
Date: 2023.11.18
Time: 12:56:38
8515600 - Battery Charger Coupler
P0E5F 00 [01100100] - Temperature too High
[HVLM_ac_temperature_derating]
Intermittent - Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 3
Fault Frequency: 1
Reset counter: 39
Mileage: 42406 km
Date: 2024.02.05
Time: 18:19:16
8515633 - Unknown Error Code
B17E0 F0 [01100100] - Unknown Error Elaboration
[HVLM_limp_home_plug_locking]
Intermittent - Not Confirmed - Tested Since Memory Clear
8515864 - AC Charging Connector Recognition
P30C1 00 [01101100] - Implausible Signal
[HVLM_no_plug_detected_AC]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 7
Reset counter: 38
Mileage: 38529 km
Date: 2023.11.29
Time: 16:54:55
2244723 - Control unit for information electronics 1
U1054 00 [00101000] - No Communication
[Information_electronics_control_module_1_no_communication]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 2
Reset counter: 25
Mileage: 39454 km
Date: 2023.12.15
Time: 07:45:39
8516406 - Unknown Error Code
C1249 F6 [00101100] - Unknown Error Elaboration
[HVLMSF_error_plug_locking_status_not_locked]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 98
Reset counter: 38
Mileage: 28957 km
Date: 2023.05.16
Time: 13:36:39
7467526 - Data Set Implausible
B2012 00 [00101111] - -
[Data_set_implausible_ECM]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Reset counter: 40
Mileage: 28849 km
Date: 2023.05.12
Time: 14:12:17
7467524 - Data Set Implausible
B2012 00 [00101111] - -
[Data_set_implausible_DCP]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 40
Mileage: 28849 km
Date: 2023.05.12
Time: 14:12:17
2498824 - Ethernet Application Server 3 for System 1 Infotainment
U1663 00 [00101000] - No Communication
[Application_server_3_system_1_infotainment_no_communication_vlan]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 2
Reset counter: 25
Mileage: 39454 km
Date: 2023.12.15
Time: 07:45:52
8516883 - Charging Socket 1
P1DD5 00 [01100100] - Connector Locking Activation Fault
[HVLM_control_plug_lock_locking_a]
Intermittent - Not Confirmed - Tested Since Memory Clear
8516871 - Unknown Error Code
B1CA2 F0 [01100100] - Unknown Error Elaboration
[HVLM_control_flap_lock_unlocking_a]
Intermittent - Not Confirmed - Tested Since Memory Clear
8516873 - Unknown Error Code
B1CA2 F1 [01101100] - Unknown Error Elaboration
[HVLM_control_flap_lock_locking_a]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 2
Reset counter: 7
Mileage: 38173 km
Date: 2023.11.24
Time: 18:48:09
8516869 - External Charging Infrastructure
P1DCB 00 [01101100] - Not Ready for Charging Socket 1
[HVLM_unknown_cp_communication_a]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 39
Reset counter: 38
Mileage: 28921 km
Date: 2023.05.16
Time: 06:51:16
8516866 - Charger for DC Charging Socket
P1DCA 00 [01100100] - Temperature too High
[HVLM_dc_temperature_derating]
Intermittent - Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 1
Reset counter: 39
Mileage: 42406 km
Date: 2024.02.05
Time: 18:19:16
8398626 - Control Module 2 for Electric Drive Power
U0292 00 [00101111] - No Communications
[EM2_01_no_communication]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 40
Date: 2023.05.12
Time: 17:04:25