CAN Gateway - 1EA 937 012 P

Coding for CAN Gateway 1EA937012P on ID.3

1EA 937 012 P :065 / :0297
Coding:
label: 1EA-937-012.clb
Faults: 2
Fault 8471814: Databus
: Received Error Message
Fault 8540417: EgoMaster
: Input Data Error
Fault 8491266: Secure Onboard Communication
: Signature Verification Failed
Fault 9371914: Predictive Route Data
: Signal Failure
Fault 1048916: Local Data Bus 4
: Electrical Malfunction
Fault 8515600: Battery Charger Coupler
: Temperature too High
Fault 8515633: Unknown Error Code
: Unknown Error Elaboration
Fault 8515864: AC Charging Connector Recognition
: Implausible Signal
Fault 8516406: Unknown Error Code
: Unknown Error Elaboration
Fault 8516883: Charging Socket 1
: Connector Locking Activation Fault
Fault 8516871: Unknown Error Code
: Unknown Error Elaboration
Fault 8516873: Unknown Error Code
: Unknown Error Elaboration
Fault 8516869: External Charging Infrastructure
: Not Ready for Charging Socket 1
Fault 8516866: Charger for DC Charging Socket
: Temperature too High
Fault 8398626: Control Module 2 for Electric Drive Power
: No Communications
Address 19: CAN Gateway (J533)       Labels: 1EA-937-012.clb
   Part No SW: 1EA 937 012 P    HW: 1EA 937 012 A
   Component: ICAS1 Host-SG 065 0297  
   Serial number: SJ8ICS061021117 Dataset Number: V03935364VL 0001
   GVL: 2D0000002608508C8062904048180040C000400000060000000000000000C057
   ASAM Dataset: EV_GatewICAS1MEB 005001
   ROD: EV_GatewICAS1MEB.rod
   VCID: 3D24337FEDFEA9C2045-8068 SFD
 
   Battery Monitoring Control Module: 
   Subsystem 1 - Part No SW: 1EA 915 181 B    HW: 1EA 915 181 A
   Component: J367-BDMConti  H04 1074 
   Serial number: 773861020021111203C2
 
   Anti-theft alarm system sensor: 
   Subsystem 2 - Part No SW: 5Q0 951 172 A    HW: 5Q0 951 172 B
   Component: Sensor, DWA    005 0403 
   Serial number: 000000000ZL21319N14Y
 
   Alarm horn: 
   Subsystem 3 - Part No SW: 5Q0 951 605 A    HW: 5Q0 951 605 A
   Component: Sirene, DWA    005 0314 
   Serial number: 00000000000050177928
 
   Multifunction steering wheel control module: 
   Subsystem 4 - Part No SW: 1EA 959 442 H    HW: 1EA 959 442 
   Component: MFL            H08 0032 
   Serial number: 17029815092032100267
 
22 Faults Found:
8471814 - Databus 
          U1123 00 [00101110] - Received Error Message
          [error_value_ESC_50_EPB_Fehlerstatus_02]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Reset counter: 40
                    Date: 2023.05.12
                    Time: 17:04:23
 
8540417 - EgoMaster 
          U15FA 00 [00100100] - Input Data Error
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
7467521 - Data Set Implausible 
          B2012 00 [00101111] - -
          [Data_set_implausible_CMS]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 28849 km
                    Date: 2023.05.12
                    Time: 14:12:17
 
7467522 - Data Set Implausible 
          B2012 00 [00101111] - -
          [Data_set_implausible_HLC]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 28849 km
                    Date: 2023.05.12
                    Time: 14:12:17
 
8491266 - Secure Onboard Communication 
          U14FE 00 [00101111] - Signature Verification Failed
          [SOK_signature_verification_failed]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 1
                    Reset counter: 40
                    Mileage: 28849 km
                    Date: 2023.05.12
                    Time: 14:13:17
 
8511745 - Unknown Error Code 
          U173E 00 [00100100] - -
          [Occupant_Presence_Service_Restriction]
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
9371914 - Predictive Route Data 
          B1630 02 [00101110] - Signal Failure
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Reset counter: 40
                    Mileage: 28850 km
                    Date: 2023.05.12
                    Time: 14:21:51
 
1048916 - Local Data Bus 4 
          U10DC 00 [00100100] - Electrical Malfunction
          Intermittent - Not Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 3
                    Mileage: 37739 km
                    Date: 2023.11.18
                    Time: 12:56:38
 
8515600 - Battery Charger Coupler 
          P0E5F 00 [01100100] - Temperature too High
          [HVLM_ac_temperature_derating]
          Intermittent - Not Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 3
                    Fault Frequency: 1
                    Reset counter: 39
                    Mileage: 42406 km
                    Date: 2024.02.05
                    Time: 18:19:16
 
8515633 - Unknown Error Code 
          B17E0 F0 [01100100] - Unknown Error Elaboration
          [HVLM_limp_home_plug_locking]
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
8515864 - AC Charging Connector Recognition 
          P30C1 00 [01101100] - Implausible Signal
          [HVLM_no_plug_detected_AC]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 7
                    Reset counter: 38
                    Mileage: 38529 km
                    Date: 2023.11.29
                    Time: 16:54:55
 
2244723 - Control unit for information electronics 1 
          U1054 00 [00101000] - No Communication
          [Information_electronics_control_module_1_no_communication]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 2
                    Reset counter: 25
                    Mileage: 39454 km
                    Date: 2023.12.15
                    Time: 07:45:39
 
8516406 - Unknown Error Code 
          C1249 F6 [00101100] - Unknown Error Elaboration
          [HVLMSF_error_plug_locking_status_not_locked]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 98
                    Reset counter: 38
                    Mileage: 28957 km
                    Date: 2023.05.16
                    Time: 13:36:39
 
7467526 - Data Set Implausible 
          B2012 00 [00101111] - -
          [Data_set_implausible_ECM]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Reset counter: 40
                    Mileage: 28849 km
                    Date: 2023.05.12
                    Time: 14:12:17
 
7467524 - Data Set Implausible 
          B2012 00 [00101111] - -
          [Data_set_implausible_DCP]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 28849 km
                    Date: 2023.05.12
                    Time: 14:12:17
 
2498824 - Ethernet Application Server 3 for System 1 Infotainment 
          U1663 00 [00101000] - No Communication
          [Application_server_3_system_1_infotainment_no_communication_vlan]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 2
                    Reset counter: 25
                    Mileage: 39454 km
                    Date: 2023.12.15
                    Time: 07:45:52
 
8516883 - Charging Socket 1 
          P1DD5 00 [01100100] - Connector Locking Activation Fault
          [HVLM_control_plug_lock_locking_a]
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
8516871 - Unknown Error Code 
          B1CA2 F0 [01100100] - Unknown Error Elaboration
          [HVLM_control_flap_lock_unlocking_a]
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
8516873 - Unknown Error Code 
          B1CA2 F1 [01101100] - Unknown Error Elaboration
          [HVLM_control_flap_lock_locking_a]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 2
                    Reset counter: 7
                    Mileage: 38173 km
                    Date: 2023.11.24
                    Time: 18:48:09
 
8516869 - External Charging Infrastructure 
          P1DCB 00 [01101100] - Not Ready for Charging Socket 1
          [HVLM_unknown_cp_communication_a]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 39
                    Reset counter: 38
                    Mileage: 28921 km
                    Date: 2023.05.16
                    Time: 06:51:16
 
8516866 - Charger for DC Charging Socket 
          P1DCA 00 [01100100] - Temperature too High
          [HVLM_dc_temperature_derating]
          Intermittent - Not Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 39
                    Mileage: 42406 km
                    Date: 2024.02.05
                    Time: 18:19:16
 
8398626 - Control Module 2 for Electric Drive Power 
          U0292 00 [00101111] - No Communications
          [EM2_01_no_communication]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 40
                    Date: 2023.05.12
                    Time: 17:04:25