ParkSteer Assist - 3AA 919 475 L

Coding for ParkSteer Assist 3AA919475L on Passat

3AA 919 475 L :H06 / :0025
Coding: 36  82  06 
label: 3AA-919-475.clb
Faults: 2
Fault 13638928: Databus
: Missing Message
Fault 13638929: Databus
: Missing Message
Fault 12656928: Databus
: Missing Message
Fault 12656929: Databus
: Missing Message
Fault 12656930: Databus
: Missing Message
Fault 12656931: Databus
: Missing Message
Fault 12850498: Databus
: Implausible Message
Fault 13637399: Databus
: Received Error Message
Fault 12648480: Databus
: Missing Message
Fault 12648481: Databus
: Missing Message
Fault 12656935: Databus
: Missing Message
# Byte 0 [36] / Binary: 00110110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-6
bit 7  
# Byte 1 [82] / Binary: 10000010
bit 0   Automatic Transmission installed
bit 1   Start/Stop System installed
bit 2  
bit 3  
bit 4   Right-Hand-Drive (RHD)
bit 5  
bit 6   Automated Rear Lid installed
bit 7   Mute Function active
# Byte 2 [06] / Binary: 00000110
bit 0-7
Address 10: Park/Steer Assist (J791)       Labels:| 3AA-919-475.clb
   Part No SW: 3AA 919 475 L    HW: 4H0 919 475 E
   Component: PARKHILFE PLA H06 0025  
   Revision: --------    Serial number: 56261307201647
   Coding: 368206
   Shop #: WSC 99999 1023 2097151
   ASAM Dataset: EV_EPHVA2C000000000 002008
   ROD: EV_EPHVA2C000000000.rod (VIN: N/A)
   VCID: 4487F917CF9BD6A925-8010
 
12 Faults Found:
13893632 - Function Restricted due to Insufficient Voltage 
          U1400 00 [008] - -
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 0 km
                    Date: 2000.00.00
                    Time: 00:00:00
 
13638928 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.06.05
                    Time: 00:17:39
 
13638929 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.06.05
                    Time: 00:17:39
 
12656928 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:20:06
 
12656929 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 254
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.04
                    Time: 04:34:14
 
12656930 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 219
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:01:04
 
12656931 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 254
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.11
                    Time: 14:42:00
 
12850498 - Databus 
          U1122 00 [008] - Implausible Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 23
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:20:06
 
13637399 - Databus 
          U1123 00 [009] - Received Error Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 0
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:00:21
 
12648480 - Databus 
          U1121 00 [009] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 0
                    Mileage: 453921 km
                    Date: 2022.06.05
                    Time: 00:17:39
 
12648481 - Databus 
          U1121 00 [009] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 0
                    Mileage: 453921 km
                    Date: 2022.06.05
                    Time: 00:17:39
 
12656935 - Databus 
          U1121 00 [008] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 33
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:19:39