Auto Dist Reg 5Q0 907 572 F coding and module information (5Q0907572F)

Coding for Auto Dist Reg 5Q0907572F / 5Q0907572F

5Q0 907 572 F :H05 / :0400
Coding: 00  00  01  00  FE  07  39 

label: 5Q0-907-572-V1.clb
# Byte 0 [00] / Binary: 00000000
bit 0-1
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [00] / Binary: 00000000
bit 0-1
bit 2   Automatic Driveaway triggered by Driver active
bit 3   Automatic Driveaway after Short Stop active
bit 4   Automatic Driveaway pre-triggered by Driver active
bit 5   Boost Function active
bit 6  
bit 7  
# Byte 2 [01] / Binary: 00000001
bit 0   Electric Parking Brake (EPB) installed
bit 1   Drive Select (PR-2H6/2H7) installed
bit 2   Front Assist Camera (PR-QK1) installed
bit 3   Trailer Recognition Control Module installed
bit 4   Automatic Transmission installed
bit 5  
bit 6  
bit 7  
# Byte 3 [00] / Binary: 00000000
bit 0-1
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 4 [FE] / Binary: 11111110
bit 0-7
# Byte 5 [07] / Binary: 00000111
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [39] / Binary: 00111001
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
Address 13: Auto Dist. Reg (J428)       Labels:| 5Q0-907-572-V1.clb
   Part No SW: 5Q0 907 572 F    HW: 5Q0 907 572 F
   Component: ACC Bosch MQB H05 0400  
   Serial number: 22111503210646
   Coding: 00000100FE0739
   Shop #: WSC 00028 028 00066
   ASAM Dataset: EV_ACCMRRBoschVW372 001016
   ROD: EV_ACCMRRBoschVW372_VW26.rod
   VCID: 3A2CC38F4CD2B64BE97-806E
 
9 Faults Found:
1067 - Brake Temperature 
          C10DF 00 [008] - -
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.1 V
                    Vehicle speed: 14.14 m/s
                    Acceleration: 0.68 m/sІ
 
1056 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_CIS_ECD_FAIL]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 2
                    Reset counter: 171
                    Mileage: 195735 km
                    Date: 2022.09.28
                    Time: 05:04:06
 
                    Control Module temperature: 16 °C
                    Voltage terminal 15: 14.6 V
                    Vehicle speed: 18.46 m/s
                    Acceleration: 0.05 m/sІ
 
1058 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_CIS_ECD_NOTAVAILABLE]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.1 V
                    Vehicle speed: 13.94 m/s
                    Acceleration: 0.45 m/sІ
 
1059 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_CIS_ESP_FAIL]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.0 V
                    Vehicle speed: 13.93 m/s
                    Acceleration: 0.46 m/sІ
 
1043 - Automatic Distance Control 
          B10E7 F0 [008] - Disconnected
          [FAULT_CIS_TSK_IRREV_FAIL]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.0 V
                    Vehicle speed: 13.96 m/s
                    Acceleration: 0.46 m/sІ
 
1117 - Automatic Distance Control 
          B10E7 F0 [008] - Disconnected
          [FAULT_CIS_TSK_REV_FAIL]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 3
                    Reset counter: 170
                    Mileage: 195731 km
                    Date: 2022.09.27
                    Time: 16:01:03
 
                    Control Module temperature: 20 °C
                    Voltage terminal 15: 14.4 V
                    Vehicle speed: 5.45 m/s
                    Acceleration: -0.72 m/sІ
 
1069 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_CIS_VXV_INVALID]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.0 V
                    Vehicle speed: 13.93 m/s
                    Acceleration: 0.46 m/sІ
 
1118 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_CIS_WHEEL_PULSE_FAIL]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.0 V
                    Vehicle speed: 13.93 m/s
                    Acceleration: 0.46 m/sІ
 
1081 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_CIS_WHEEL_RPM_FAIL]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 4
                    Reset counter: 171
                    Mileage: 195730 km
                    Date: 2022.09.27
                    Time: 15:04:09
 
                    Control Module temperature: 30 °C
                    Voltage terminal 15: 13.0 V
                    Vehicle speed: 13.92 m/s
                    Acceleration: 0.47 m/sІ