Telephone - 5N0 035 729 A

Coding for Telephone 5N0035729A on Golf Cabrio

5N0 035 729 A :H05 / :0315
Coding: 0A  00  00  00  80  01  01  00 
label: 5N0-035-729.clb
# Byte 0 [0A] / Binary: 00001010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 4 [80] / Binary: 10000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 5 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 7 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 77: Telephone (J412)       Labels:| 5N0-035-729.clb
   Part No SW: 5N0 035 729 A    HW: 5N0 035 729 A
   Component: TELEFON       H05 0315  
   Revision: 1B001001    Serial number: 00007665579162
   Coding: 0A00000080010100
   Shop #: WSC 01383 790 50316
   ASAM Dataset: EV_UHVUMI 001007
   ROD: EV_UHVUMI.rod
   VCID: 2E59537A71174CF9E3-807A
 
3 Faults Found:
9457426 - Left audio channel for speech/telephone 
          B104F 12 [009] - Short to GND
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 254
                    Mileage: 166572 km
                    Date: 2022.07.31
                    Time: 16:26:33
 
9457170 - Right audio channel for speech/telephone 
          B104E 12 [009] - Short to GND
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 254
                    Mileage: 166572 km
                    Date: 2022.07.31
                    Time: 16:26:33
 
9458195 - Control Module for Cellular Telephone 
          B1052 13 [008] - Open Circuit
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 13
                    Mileage: 172327 km
                    Date: 2022.10.18
                    Time: 17:16:18
  
End-------------------------(Elapsed Time: 03:38)--------------------------