Door Elect Pass - 3AA 959 702 A

Coding for Door Elect Pass 3AA959702A on Passat

3AA 959 702 A :002 / :0533
Coding: 02  00  B6 
label: 3C0-959-70X-GEN4.clb
Faults: 6
Fault 65538: Local Data Bus
: No Communication
Fault 66048: Motor for Front Window Regulator
: Missing Calibration / Basic Setting
Fault 67330: Switch for Central Locking
: Signal Implausible
Fault 67589: Turn Signal in Exterior Mirror
: Electrical Failure
Fault 65793: Supply voltage
: Voltage too Low
Fault 131329: Rear Door Control Module
: Supply Voltage too Low
# Byte 0 [02] / Binary: 00000010
bit 0  
bit 1   Start/Stop System active/installed [PR-7L6]
bit 2   Mode for PQ25 (instead PQ35)
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [00] / Binary: 00000000
bit 0   Seat Memory AND/OR Mirror with Memory Function installed
bit 1   Right-Hand-Drive (RHD) [PR-L0R]
bit 2   Safe-Motor NOT installed [PR-4I2/5C1]
bit 3   Pinch Protection inactive
bit 4   Folding Mirrors installed [PR-6XE/6XK]
bit 5  
bit 6  
bit 7  
# Byte 2 [B6] / Binary: 10110110
bit 0   Rear Lid Remote Unlock Button (E233) installed
bit 1   Ambient Mirror Illumination installed
bit 2   Mirror Turn Signals installed [STANDARD]
bit 3   Interior Door Handle Illumination installed [PR-QQ4/QQ6]
bit 4   Automatic Run active [STANDARD]
bit 5   Mirror Heater installed [PR-6XD/6XE/6XJ/6XK]
bit 6   Door Exit/Warning Light installed [PR-QQ4]
bit 7   Rear Door Control Modules installed
Address 52: Door Elect, Pass. (J387)       Labels:| 3C0-959-70X-GEN4.clb
   Part No SW: 3AA 959 702 A    HW: 3C0 959 792 C
   Component: TUER-SG BT    002 0533  
   Revision: 14110009    Serial number: 0006736880
   Coding: 0200B6
   Shop #: WSC 05311 115 00000
   ASAM Dataset: EV_TSGBPQ35BRFVW46X A04001
   ROD: EV_TSGBPQ35BRFVW46X_VW32.rod
   VCID: 366393DF89477439AB-8062
 
6 Faults Found:
65538 - Local Data Bus 
          U10BA 00 [009] - No Communication
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 0
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:00:02
 
66048 - Motor for Front Window Regulator 
          B11EC 54 [009] - Missing Calibration / Basic Setting
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 7
                    Fault Frequency: 4
                    Reset counter: 0
 
67330 - Switch for Central Locking 
          B122D 29 [008] - Signal Implausible
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 7
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.04
                    Time: 21:41:30
 
67589 - Turn Signal in Exterior Mirror 
          B11FD 01 [008] - Electrical Failure
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.11
                    Time: 02:16:11
 
65793 - Supply voltage 
          U1011 00 [009] - Voltage too Low
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 2
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.11
                    Time: 02:10:00
 
131329 - Rear Door Control Module 
          B11ED F0 [008] - Supply Voltage too Low
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.11