Auto Dist Reg - 5Q0 907 567 P

Coding for Auto Dist Reg 5Q0907567P on Tiguan

5Q0 907 567 P :H10 / :0100
Coding: 00  1E  1B  00  FE  03  0B 
label: 5Q0-907-567.clb
Faults: 0
# Byte 0 [00] / Binary: 00000000
bit 0-1
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [1E] / Binary: 00011110
bit 0-1
bit 2   Automatic Driveaway triggered by Driver active
bit 3   Automatic Driveaway after Short Stop active
bit 4   Automatic Driveaway pre-triggered by Driver active
bit 5   Boost Function active
bit 6  
bit 7  
# Byte 2 [1B] / Binary: 00011011
bit 0   Electric Parking Brake (EPB) installed
bit 1   Drive Select (PR-2H6/2H7) installed
bit 2   Front Assist Camera (PR-QK1) installed
bit 3   Trailer Recognition Control Module installed
bit 4   Automatic Transmission installed
bit 5  
bit 6  
bit 7  
# Byte 3 [00] / Binary: 00000000
bit 0-1
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 4 [FE] / Binary: 11111110
bit 0-7
# Byte 5 [03] / Binary: 00000011
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [0B] / Binary: 00001011
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
Address 13: Auto Dist. Reg (J428)       Labels:| 5Q0-907-567.clb
   Part No SW: 5Q0 907 567 P    HW: 5Q0 907 567 L
   Component: ACC3          H10 0100  
   Serial number: 06051403030094 Dataset Number: 5g0114v____ 0015
   Coding: 001E1B00FE030B
   Shop #: WSC 00028 028 00333
   ASAM Dataset: EV_ACCBoschMQB 001024
   ROD: EV_ACCBoschMQB_VW37.rod
   VCID: 489FED27F3B3F2D14B-801C
 
1 Fault Found:
1117 - Automatic Distance Control 
          B10E7 F0 [00101000] - Disconnected
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 244
                    Mileage: 145144 km
                    Date: 2023.12.26
                    Time: 04:28:06
 
                    Control Module temperature: 2 °C
                    Voltage terminal 15: 11.0 V
                    Vehicle speed: 0.00 m/s
                    Acceleration: 0.00 m/sІ