Address 08: Auto HVAC (J255) Labels:| 5G0-907-044.clb
Part No SW: 5G0 907 044 BH HW: 5G0 907 044 BH
Component: Climatronic H04 1202
Revision: 00001K10
Coding: 1202010420410101101550000010180A
Shop #: WSC 00015 115 08193
ASAM Dataset: EV_ACClimaBHBVW37X 005137
ROD: EV_ACClimaBHBVW37X_005_VW37.rod
VCID: 6E8533D0F010B96B2D3-803A
Fresh air blower control module (front):
A/C pressure/coolant temperature sensor:
Air quality sensor:
Humidity sensor: exterior:
5 Faults Found:
327937 - Motor for Left Temperature Flap
B108C 12 [008] - Short to Plus
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 22
Mileage: 283468 km
Date: 2023.10.08
Time: 15:42:30
Voltage terminal 30: 12.8 V
Outside temperature: 6.0 °C
Inside temperature: 23.2 °C
Left temperature flap - actual value: 172
Left temperature flap - actual value: 70.0 %
Temperature door left - Specified value: 170
327938 - Motor for Left Temperature Flap
B108C 11 [008] - Short to Ground
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 14
Reset counter: 32
Mileage: 282573 km
Date: 2023.10.04
Time: 08:32:40
Voltage terminal 30: 14.3 V
Outside temperature: 6.5 °C
Inside temperature: 21.4 °C
Left temperature flap - actual value: 128
Left temperature flap - actual value: 47.5 %
Temperature door left - Specified value: 126
328199 - Position Sensor for Right Temperature Flap Motor
B1095 15 [008] - Open or Short to Plus
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 2
Reset counter: 30
Mileage: 283772 km
Date: 2023.10.10
Time: 08:47:03
Voltage terminal 30: 12.2 V
Outside temperature: -4.0 °C
Inside temperature: 0.8 °C
Right temperature flap: actual value: 235
Right temperature flap: actual value: 100.0 %
Temperature door right - Specified value: 234
263425 - Air Quality Sensor
B10AF 04 [008] - Internal System Fault
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 3
Fault Frequency: 9
Reset counter: 25
Mileage: 283246 km
Date: 2023.10.08
Time: 10:11:08
Voltage terminal 30: 14.4 V
Outside temperature: 1.0 °C
System run time-Engine running time: 35 s
System run time-Terminal 15 on: 37 s
263682 - Exterior Air Quality/Humidity Sensor
B137A 31 [008] - No Signal
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 3
Fault Frequency: 55
Reset counter: 32
Mileage: 282434 km
Date: 2023.10.03
Time: 09:39:20
Voltage terminal 30: 14.6 V
Outside temperature: 10.0 °C
System run time-Engine running time: 255 s
System run time-Terminal 15 on: 255 s