CAN Gateway 1K0 907 530 S coding and module information (1K0907530S)

Coding for CAN Gateway 1K0907530S / 1K0907951

1K0 907 530 S :H-- / :0210
Coding: E9  81  7F  06  00  02  02  00  01  02 

label: 1K0-907-530-V4.clb
# Byte 0 [E9] / Binary: 11101001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [81] / Binary: 10000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [7F] / Binary: 01111111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [06] / Binary: 00000110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 4 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 5 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 7 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 9 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 19: CAN Gateway        Labels:. 1K0-907-530-V4.clb
   Part No SW: 1K0 907 530 S    HW: 1K0 907 951 
   Component: J533__Gateway   H-- 0210  
   Revision:   H--       Serial number: 00000000000000
   Coding: E9817F06000202000102
   Shop #: WSC 12345 123 12345
   VCID: 3778BEFD465BB13EFA-8062
 
1 Fault Found:
00470 - Company Comfort Databus in Single Wire 
            011 - Open Circuit
             Freeze Frame:
                    Fault Status: 01101011
                    Fault Priority: 3
                    Fault Frequency: 60
                    Reset counter: 20
                    Mileage: 182392 km
                    Time Indication: 0
                    Date: 2020.10.26