Auto HVAC 3T0 907 044 AR coding and module information (3T0907044AR)

Coding for Auto HVAC 3T0907044AR / 3T0907044AR

3T0 907 044 AR :H15 / :0401
Coding: 00  00  00  10  02 

label: 5K0-907-044.clb
# Byte 0 [00] / Binary: 00000000
bit 0-5
bit 6  
bit 7  
# Byte 1 [00] / Binary: 00000000
bit 0-2
bit 3   Extended Display Temperature Range active
bit 4   Function Light Dimming via Light Sensor active
bit 5  
bit 6  
bit 7  
# Byte 2 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3-5
bit 6  
bit 7  
# Byte 3 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-6
bit 7   Blower/Display Logic for absolute Blower Voltage without Blower Stage Display
# Byte 4 [02] / Binary: 00000010
bit 0  
bit 1-3
bit 4  
bit 5  
bit 6   Compressor Shutoff via Humidity Sensor active
bit 7  
Address 08: Auto HVAC (J255)       Labels:| 5K0-907-044.clb
   Part No SW: 3T0 907 044 AR    HW: 3T0 907 044 AR
   Component: Climatronic   H15 0401  
   Revision: 00005001    
   Coding: 0000001002
   Shop #: WSC 33361 790 00999
   ASAM Dataset: EV_Climatronic A01006
   ROD: EV_ClimaAutoBasis_SK46.rod
   VCID: 025D882184800297DCD-8056
 
3 Faults Found:
13701888 - Function Restriction due to Faults in Other Modules 
          U1113 00 [009] - -
          [Tip-TNF 212454]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 10
                    Reset counter: 27
                    Mileage: 57755 km
                    Date: 2020.09.24
                    Time: 00:04:54
 
13701968 - Function Restriction due to Faults in Other Modules 
          U1113 00 [008] - -
          [Tip-TNF 227052]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 6
                    Reset counter: 67
                    Mileage: 57755 km
                    Date: 2020.09.24
                    Time: 00:04:54
 
9479189 - Signal Line for Air Quality Sensor 
          B10A4 15 [008] - Open or Short to Plus
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 3
                    Fault Frequency: 3
                    Reset counter: 67
                    Mileage: 57755 km
                    Date: 2020.09.24
                    Time: 17:48:46