Address 13: Auto Dist. Reg (J428) Labels:| 2Q0-907-572.clb
Part No SW: 2Q0 907 572 M HW: 2Q0 907 572 B
Component: ACCCONTIMQB H02 0233
Coding: 2A00608140FF8728749C8145604085
Shop #: WSC 00049 770 00137
ASAM Dataset: EV_ACCMRRCONTIVW376 002012
ROD: EV_ACCMRRCONTIVW376_002.rod
VCID: 3E24CFD790FACFB743B-806A
7 Faults Found:
2101 - Databus
U1123 00 [009] - Received Error Message
[FAULT_ESP_STATUS_SYSTEM]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 4
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:16:58
Voltage terminal 15: 11.7 V
Control Module temperature: 43 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.03 m/s²
Status_ACC_System: ACC_irreversible error
2068 - Databus
U1123 00 [009] - Received Error Message
[FAULT_TSK_IRREV_FAIL]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:18:15
Voltage terminal 15: 11.7 V
Control Module temperature: 45 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.03 m/s²
Status_ACC_System: ACC_irreversible error
2062 - Databus
U1123 00 [009] - Received Error Message
[FAULT_MAINSWITCH_FAIL]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 4
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:16:58
Voltage terminal 15: 11.7 V
Control Module temperature: 43 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.03 m/s²
Status_ACC_System: ACC_irreversible error
1116 - Databus
U1122 00 [009] - Implausible Message
[FAULT_TSK_CODING_IN_PLAUS_PHASE_FAIL]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:16:58
Voltage terminal 15: 11.8 V
Control Module temperature: 43 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.06 m/s²
Status_ACC_System: ACC_irreversible error
2052 - Databus
U1123 00 [009] - Received Error Message
[FAULT_ALP_STEERINGWHEEL_FAIL]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 4
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:16:58
Voltage terminal 15: 11.7 V
Control Module temperature: 43 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.03 m/s²
Status_ACC_System: ACC_irreversible error
2049 - Databus
U1123 00 [009] - Received Error Message
[FAULT_ALP_DT_STEERING_WHEEL_FAIL]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 4
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:16:58
Voltage terminal 15: 11.7 V
Control Module temperature: 43 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.03 m/s²
Status_ACC_System: ACC_irreversible error
2127 - Databus
U1123 00 [009] - Received Error Message
[FAULT_OP_FAIL]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 4
Fault Frequency: 2
Reset counter: 111
Mileage: 1372 km
Date: 2018.06.13
Time: 15:16:58
Voltage terminal 15: 11.7 V
Control Module temperature: 43 °C
Velocity_vehicle_reference: 0.00 m/s
Longitudinal_acceleration_vehicle_reference: -0.06 m/s²
Status_ACC_System: ACC_irreversible error