Distanzregelung 5Q0 907 572 R coding and module information (5Q0907572R)

Coding for Distanzregelung 5Q0907572R / 5Q0907572H

5Q0 907 572 R :H10 / :0771
Coding: 35  1F  7F  EA  DD  FF  CF  68  87  97  81  E4  81  40  86  00  00  00  00  00  00  B9  40  00  06 

label: 3Q0-907-572.clb
# Byte 0 [35] / Binary: 00110101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-6
bit 7  
# Byte 1 [1F] / Binary: 00011111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [7F] / Binary: 01111111
bit 0  
bit 1  
bit 2  
bit 3   Speed Limit Assistent active
bit 4  
bit 5   Overtaking Right Prevention active
bit 6   Overtaking Assistance active
bit 7  
# Byte 3 [EA] / Binary: 11101010
bit 0-2
bit 3   Control Module for Trailer Recognition installed [PR-1D2/1M6]
bit 4  
bit 5  
bit 6   Front Camera installed [PR-QK1]
bit 7   Drive Mode Selection via Instrument Cluster
# Byte 4 [DD] / Binary: 11011101
bit 0  
bit 1  
bit 2   Emergency Assist installed
bit 3  
bit 4   Electric Parking Brake (EPB) installed [PR-UH1/UH2]
bit 5  
bit 6  
bit 7  
# Byte 5 [FF] / Binary: 11111111
bit 0-7
# Byte 6 [CF] / Binary: 11001111
bit 0-7
# Byte 7 [68] / Binary: 01101000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-7
# Byte 8 [87] / Binary: 10000111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-7
# Byte 9 [97] / Binary: 10010111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-7
# Byte 10 [81] / Binary: 10000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-7
# Byte 11 [E4] / Binary: 11100100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 12 [81] / Binary: 10000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 13 [40] / Binary: 01000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 14 [86] / Binary: 10000110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 15 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 16 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 17 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 18 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 19 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 20 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 21 [B9] / Binary: 10111001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 22 [40] / Binary: 01000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 23 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 24 [06] / Binary: 00000110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Adresse 13: Distanzregelung (J428)       Labeldatei:| 3Q0-907-572.clb
   Teilenummer SW: 5Q0 907 572 R    HW: 5Q0 907 572 H
   Bauteil: ACC BOSCH MQB H10 0771  
   Codierung: 351F7FEADDFFCF68879781E4814086000000000000B9400006
   Betriebsnr.: WSC 00046 000 00000
   ASAM Datensatz: EV_ACCBOSCHVW416 003014
   ROD: EV_ACCBOSCHVW416_002_VW37.rod
   VCID: 46DE3CAE782E737B09C-8012
 
Kein(e) Fehlercode(s) gefunden.