Address 17: Instruments (J285) Labels:| 3C8-920-xxx-17.clb-SRI1
Part No SW: 3AA 920 880 H HW: 3AA 920 880 H
Component: KOMBI H05 0505
Serial number: 00000000000000
Coding: 161F01
Shop #: WSC 05314 115 00000
ASAM Dataset: EV_Kombi_UDS_VDD_RM09 A04716
ROD: EV_Kombi_UDS_VDD_RM09_004_VW46.rod (VIN: N/A)
VCID: 387F9DE783538249B9-806C
8 Faults Found:
9453330 - Outside temperature sensor
B103F 1B [009] - Resistance Too High
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 0
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:04
9453842 - Oil Level Thermal Sensor
B1041 35 [009] - Signal High Time > Maximum
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 0
Mileage: 453921 km
Date: 2022.06.08
Time: 00:00:19
12648448 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 0
Mileage: 453921 km
Date: 2022.06.05
Time: 00:17:39
12656896 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 51
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.11
Time: 14:42:05
13638912 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 453921 km
Date: 2022.06.05
Time: 00:17:39
12718592 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 453921 km
Date: 2022.06.06
Time: 01:00:44
12658688 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 98
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.11
Time: 14:41:59
13635840 - Supply voltage
U1011 00 [008] - Voltage too Low
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 3
Reset counter: 40
Mileage: 453921 km
Date: 2022.06.19
Time: 01:06:27